< back to member

 

Beacon project:

PATIO HAUS - PASSIVHAUS EN SEVILLA

41005 SEVILLA, Other associated region, Spain
Contact Castaño Salvador, Juan Manuel

See www.passivehouse-database.org for more information

Juan Manuel Castaño
Juan Manuel Castaño / PatioHaus
Juan Manuel Castaño / PatioHaus
Juan Manuel Castaño / PatioHaus
Juan Manuel Castaño / PatioHaus
Juan Manuel Castaño / PatioHaus

 

Website

www.arquitectocastano.com


Email


Timeline

Beacon Timeline 2012 2013 2014 2015 2016 2017 2018 2019 2020
May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Pre Design Building specification                                                                                                                                                                                                                
Planning                                                                                                                                                                                                                
Design Preliminary design                                                                                                                                                                                                                
Working design                                                                                                                                                                                                                
Detailed Design Detailed design/elaboration                                                                                                                                                                                                                
Construction Construction                                                                                                                                                                                                                
Commissioning/handover                                                                                                                                                                                                                
Occupancy & Operation Post ccupancy commissioning                                                                                                                                                                                                                
Ordinary operation                                                                                                                                                                                                                
Monitoring Energy performance measurements                                                                                                                                                                                                                
Quality Assurance Info session                                                                                                                                                                                                                
Airtightness test                                                                                                                                                                                                                
Thermographic imaging                                                                                                                                                                                                                
On-site training of workers                                                                                                                                                                                                                
Building vertification                                                                                                                                                                                                                
Renewable technology certification                                                                                                                                                                                                                
User comfort survey                                                                                                                                                                                                                

General description

This is a contemporary approach, of a traditional in between neighbours andalousian “patio” house. Among the PH strategies, the patio is the climatic “heart” of the house, it has a glass motoriced roof, that is closed in winter creating a greenhouse effect, and open in summer creating the traditional cold well effect. The house uses also the support in the roof and in the patio of evaporative cooling, troughout plants, roof pool, and a “window fountain” in the patio. The PHPP calculations results are in accordance with the tradicional experience: This kind of shadowed patio houses in between neighbours are fresh, even in Sevilla, as the heating demand in winter is bigger than the cooling demand in summer. ARCHITECT: JUAN MANUEL CASTAÑO SALVADOR / QUANTITY SURVEYOR: JUAN MANUEL CASTAÑO REYES / STATIC ENGINEER: CALCONSA – ALEJANDRO MORAL / FACILITIES: JUAN MANUEL CASTAÑO SALVADOR / COLLABORATION ARCHITECT: JOSE ANTONIO PLAZA - PAULA C. GARCÍA CARRASCO / PHPP CALCULATIONS: JUAN MANUEL CASTANO + MICHEEL WASSOUF /


Project type

New build


Project scale

individual building


Ownership type

privately owned


Building type and size

terraced house


Treated Floor Area according to PHPP

211,5m²


Gross construction costs

840 (EUR/m² of Treated Floor Area)


Gross building strucutre + technical service costs

770 (EUR/m² of Treated Floor Area)


Passive house database

Find this project at www.passivehouse-database.org




Intelligent Energy Europe
Partner
PassREg
Passive House Regions with Renewable Energies