General description
Passive house, nearly zero energy residential building. Solar photovoltaic systems are integrated in the roof. Air to hearth heat exchanger integrated in mechanical ventilation system.
Project type
New build
Project scale
individual building
Ownership type
privately owned
Building type and size
detached single family house
Treated Floor Area according to PHPP
175m²
Energy efficiency and use of renewables
High thermal insulation of envelope was reached with thermal transmittance values of 0,127 W/(m2K) for external walls, 0,146 W/(m2K) for the basement, 0,138 W/(m2K) for the roof, 0,70 W/(m2K) for the glazed surfaces and 0,80 for the frames. External automatic solar blinds are installed for solar shading when it needs. A mechanical ventilation system with heat recovery is completed by a an horizontal earth to air heat exchanger (about 150 m long at depth of 1,2 m below the ground). A reversible high efficiency heat pump is installed. A photovoltaic systems is installed on the roof. --> Project team: Architetti Associati Cappelletti & Cerliani (Mariano C.se)